Wrnk-391-02 armored thermocouple




Product Name: wrnk-391-02 armored thermocouple
Product No.: 134838-792
Product model: wrnk-391-02
Updated on: July 1, 2009
Manufacturer: thermocouple, thermal resistance, bimetal thermometer, polytetrafluoroethylene, PTFE gasket -- Shanghai Feilong instrument and Electrical Co., Ltd
Customized: can be customized according to the needs of customers
Views:
Product details
Wrnk armored thermocouple   





Model, division number and recommended temperature of armored thermocouples of different materials and diameters


Electrode materials Model Graduation Shell material Shell diameter(mm) Recommended operating temperature ℃
Maximum temperature for long-term use Maximum temperature for short-term use
Nickel chromium -- nickel silicon  WRKK K GH3030 0.25; 300 600
NiCr-NiSi (WRNK) 0.5;1.0 500
    1.5;2.0;3.0 800 900
    4.0;4.5;5.0 900 1000
    6.0;8.0 1000 1100
    1Cr18Ni9Ti 0.25; 300 600
    0.5;1.0 400
    1.5;2.0 600 700
    3.0;4.0;4.5 800 900
    5.0;6.0;8.0
Nickel chromium silicon -- nickel silicon  WRNK N GH3030 0.25; 300 600
NiCrSi-NiSi (WRMK) 0.5;1.0 500
    1.5;2.0;3.0 800 900
    4.0;4.5;5.0 900 1100
    6.0;8.0 1000 1200
    1Cr18Ni9Ti 0.25; 300 600
    0.5;1.0 500
    1.5;2.0 600 700
    3.0;4.0;4.5 800 900
    5.0;6.0;8.0
Nickel chromium copper nickel  WREK E 1Cr18Ni9Ti 0.5;1.0 400 500
NiCr-CuNi 1.5;2.0; 500 600
  3.0;4.0;4.5;5.0 600 700
  6.0;8.0 700 800
铁--铜镍  WRJK J 1Cr18Ni9Ti 0.5;1.0 300 400
Fe-CuNi (WRFK) 1.5;2.0; 400 500
    3.0;4.0;4.5;5.0 500 600
    6.0;8.0 600 750
Copper nickel copper  WRTK T 1Cr18Ni9Ti 0.5;1.0 200 250
Cu-CuNi (WRCK) 1.5;2.0;3.0;4.0 250 300
    4.5;5.0
    6.0;8.0 300 350
Platinum Rhodium 10 -- platinum WRSK S GH3030 2.0; 1000 1050
PtRh10-Pt (WRPK) 3.0;4.0;4.5 1100 1200
    5.0;6.0;8.0
Platinum rhodium 13 -- platinum  WRRK R GH3030 2.0; 1000 1100
PtRh13-Pt (WRQK) 3.0;4.0;4.5 1100 1200
    5.0;6.0;8.0
Platinum rhodium 30 -- platinum rhodium 6 WRBK B GH3030 2.0; 1000 1050
PtRh30-PtRh6 (WRRK) 3.0;4.0;4.5 1100 1200


*The model marked in brackets in the column of model number is the method used in the past.


● temperature measurement range and accuracy of commonly used armored thermocouple (class II) on site


GraduationTemperature measurement range (℃) Tolerance (reference end is 0 ℃)
K、N -40~1100 ±2.5℃或±0.0075∣t∣
E -40~800
J -40~750
T -40~350 ±1.0℃或±0.0075∣t∣
Note: "t" refers to the temperature to be measured; in the two tolerance values given in the same column, whichever is the greater.

● When the temperature of armored thermocouple changes in a step, the time required for the output value of thermocouple to change to a specified percentage of the step change is called the thermal response time, which is expressed by τ (expressed by τ 0.5 when taking 50%).


Thermal response time of armored thermocouple


Thermal response time τ 0.5 (s)

Casing diameter D (mm) Shell type (≤) Insulation type (≤)
2 0.4 0.5
3 0.6 1.2
4 0.8 2.5
5 1.2 4
6 2 6
8 4 8


● insulation resistance
When the ambient air temperature is 20 ± 15 ℃ and the relative humidity is not more than 80%, the insulation resistance between the thermal pole and the outer sleeve of the insulated armored thermocouple shall meet the requirements of the following table:


Diameter of armored couple D (mm) Test voltage DCV Insulation resistance m Ω· M
0.25 50±5 ≥100
0.5~1.5 50±5 ≥1000
﹥1.5 500±50 ≥1000


Note: the insulation resistance is expressed in M Ω· m, that is, the normal temperature insulation resistance and armored couple
Product of length.
For example, 1000m Ω· m means that the insulation resistance of 1m long sample is
1000m Ω, insulation resistance of 10m long sample is 100m Ω.
For armour couple with length less than 1m, it is calculated as 1m.
Socket type junction box and armored thermocouple with compensation wire are not included in this example.




Basic structure of armored thermocouple
Armored thermocouple is mainly composed of junction box, terminal and armored thermocouple elements, and equipped with various installation and fixing devices.




● installation and fixation type:
The fixture is for the user to install. Armored thermocouple has five structural types: no fixed device, fixed ferrule type, movable ferrule type, fixed flange type and movable flange type. The fixed ferrule type is only for one-time fixed use, and the movable ferrule type can be used for multiple fixed uses.




Ferrule thread (unit: mm)




Size of ferrule thread joint


Diameter of protection pipe >4 ≤4
M16×1.5 M12×1.5
22 19
Ferrule flange (unit: mm)


● reference end type of armored thermocouple
The junction box is used to connect the reference end of thermocouple and display instrument. There are simple type, splash proof type, waterproof type, explosion-proof type, small junction box type, plug-in type, compensation wire type and other structural types.
Schematic (partial):




Different combinations of armored thermocouples and ordering instructions
The following gives the naming methods of several combinations of different fixed installation forms and different reference ends. By referring to these combinations, as well as the previous "model meaning" and "armored thermocouple example", you can easily name the thermocouple you need.
The following figure also shows the thermocouple length L and sleeve diameter d that should be noted when ordering. When ordering and naming, the thermocouple with 1Cr18Ni9Ti stainless steel sleeve, single piece type and class II precision need not be noted separately.




● thermocouple installation method




1、 Installation method on curved pipe II, installation method of inclined pipe through axis
 


三,垂直管通轴线的安装方法 四,锅炉烟道中的密封安装方法


 
 









  






  • Previous page:Wrnk-187 armored thermocouple
  • Next page:Wzpk-231 armored thermocouple



  • Relevant news
    Title:High temperature and high pressure thermocouple installation structure diagram
    Introduction:...... [More]
     